home *** CD-ROM | disk | FTP | other *** search
/ Spec Disk 1998 Spring 4.0 / Spec Disk 1998 Spring 4.0.iso / generic / 08462dor.gen < prev    next >
Text File  |  1998-06-10  |  17KB  |  265 lines

  1.     SECTION 08462
  2.  
  3.     AUTOMATIC SLIDING DOORS
  4. NOTE ** Dor-O-Matic, aluminum and all-glass sliding door packages, operators, actuators, and safeties.
  5. NOTE ** 
  6. NOTE ** This section is based on the products of Dor-O-Matic, which is located at:
  7. NOTE **    7530 W. Wilson Avenue
  8. NOTE **    Harwood Heights, IL  60656-4786
  9. NOTE **    Tel:  (708) 867-7400
  10. NOTE **    Tel:  (800) 543-4635
  11. NOTE **    Fax:  (708) 867-0291
  12. NOTE ** 
  13. NOTE ** Dor-O-Matic is one of the oldest, most experienced, and most innovative manufacturers of automatic door equipment in the world.  This section covers only a part of their product line:  "Astro-Slide," "Astro-Glass," and "Astro-Scopic" sliding doors and operators, with accompanying control components, including motion detectors and advanced infrared and photoelectric safety systems.  See their other sections for automatic swinging doors, automatic bifolding doors, fire door operators, and ADA-compliant low-energy operators.
  14. NOTE ** 
  15. NOTE ** SECTION 08462 - AUTOMATIC SLIDING DOORS, Copyright 1997, The Architect's Catalog, Inc.
  16.  
  17. PART 1    GENERAL
  18.  
  19. 1.1    SECTION INCLUDES
  20. NOTE ** Delete items below not required for project.
  21.  
  22.     A.    Aluminum sliding doors and frames.
  23.  
  24.     B.    All-glass sliding doors and frames.
  25.  
  26.     C.    Automatic door operators, actuators, and safeties.
  27.  
  28.     D.    Sidelights and transoms.
  29.  
  30. 1.2    RELATED SECTIONS
  31. NOTE ** Delete any sections below not relevant to this project; add others as required.
  32.  
  33.     A.    Section 03300 - Cast-in-Place Concrete:  Recess in concrete slab for track at sidelight areas.
  34. NOTE ** If aluminum doors and frames are not specified in this section, they may be specified in Section 08120 - Aluminum Doors, in Section 08410 - Entrances and Storefronts, or in Section 08910 - Metal-Framed Curtain Wall, or any number of other narrowscope sections.  Verify method used for this project.
  35.  
  36.     B.    Section _____ - ___________:  Aluminum doors and frames.
  37.  
  38.     C.    Section 08211 - Flush Wood Doors.
  39. NOTE ** Verify electrical circuit capacity required, for operator and all its actuators and safeties.
  40.  
  41.     D.    Division 16 - Electrical:  115 VAC, single-phase wiring in conduit between operator enclosure and building power supply and low voltage wiring between enclosure and actuators and safeties.
  42.  
  43.     E.    Division 16 - Electrical:  115 VAC, single-phase wiring in conduit between operator enclosure and remote switch station.
  44.  
  45. 1.3    REFERENCES
  46.  
  47.     A.    ANSI/BHMA A156.10 - American National Standard for Power-Operated Pedestrian Doors.
  48.  
  49.     B.    UL 325 - Standard for Door, Drapery, Gate, Louver, and Window Operators and Systems.
  50.  
  51. 1.4    SUBMITTALS
  52.  
  53.     A.    Submit under provisions of Section 01300.
  54.  
  55.     B.    Product Data:  Manufacturer's catalog data, detail sheets, and specifications.
  56.  
  57.     C.    Shop Drawings:  Prepared specifically for this project; show dimensions of doors, operators, and interface with other products.
  58.  
  59.     D.    Operating and Maintenance Data:  Operating and maintenance instructions, parts lists, and wiring diagrams.
  60.  
  61. 1.5    QUALITY ASSURANCE
  62.  
  63.     A.    Installer Qualifications:  Factory-trained, with minimum 3 years experience.
  64.  
  65. 1.6    WARRANTY
  66.  
  67.     A.    Provide manufacturer's warranty for roller track for five years from date of completion.
  68.  
  69. PART 2    PRODUCTS
  70.  
  71. 2.1    MANUFACTURERS
  72.  
  73.     A.    Acceptable manufacturer:  Provide products made by Dor-O-Matic, 7350 West Wilson Avenue, Harwood Heights, IL 60656-4786.  ASD.  Tel: (708) 867-7400 or (800) 543-4635.  Fax: (708) 867-0291.
  74.  
  75.     B.    Requests for substitutions will be considered in accordance with provisions of Section 01600.
  76. NOTE ** Delete paragraph above or below;  coordinate with Division 1 requirements.
  77.  
  78.     C.    Substitutions:  Not permitted.
  79.  
  80.     D.    Provide all door operators from a single manufacturer.
  81.  
  82. 2.2    DOORS AND FRAMES
  83. NOTE ** Automatic sliding doors usually come in complete packages including doors, frames, operators, and actuators.  In addition, virtually any door type (aluminum, hollow metal, wood) can be substituted for the manufacturer's standard doors.  Telescoping doors are available only in extruded aluminum ("Astro-Scopic").  The standard finishes for aluminum doors are dark bronze and natural anodized aluminum, but many other finishes are available, including Kynar(tm) and metal-clad.
  84.  
  85.     A.    Automatic Sliding Doors:  Heavy duty anodized extruded aluminum header and jambs, with interlocked sections and thru-rod bolted connections; complete with doors, sidelights, transom, and all hardware and accessories; complying with ANSI/BHMA A156.10 and UL 325.
  86. NOTE ** Delete all but one of the following functional descriptions.
  87.         1.    Type:  Bi-parting, two sliding leaves.
  88.         2.    Type:  Single sliding, one sliding leaf.
  89.         3.    Type:  Bi-parting and telescoping, six sliding leaves.
  90.         4.    Type:  Single sliding and telescoping, three sliding leaves.
  91. NOTE ** Delete all but one of the following three paragraphs.  "Astro-Glass" (tempered all-glass doors and sidelights) must slide on the outside.  If doors have no sidelights (sliding into pockets or on outside face of building), consult the manufacturer for limitations on breakaway function, configuration of frame and header, and locking.  Use the third option only if breakaway is not required at all -- only if the doors do not need to qualify as an emergency exit.
  92.         5.    Doors sliding on outside of fixed sidelights.
  93.         6.    Doors sliding on inside of breakaway sidelights.
  94.         7.    Non-breakaway doors sliding on inside of fixed sidelights.
  95. NOTE ** Delete all but one of the following four paragraphs or enter another description of the actuators.
  96.         8.    Actuators:  Motion detector, both sides.
  97.         9.    Actuators:  Push plate, one side; motion detector, other side.
  98.         10.    Actuators:  Mat-type, both sides.
  99.         11.    Actuators:  ________.
  100.         12.    Safety:  Overhead-mounted infrared presence detector and safety beams in door opening.
  101. NOTE ** Delete all but one of the following five finish paragraphs.  Dark bronze and natural anodizing are standard options -- all other finishes are extra.
  102.         13.    Finish:  Dark bronze anodized.
  103.         14.    Finish:  Natural aluminum anodized.
  104.         15.    Finish:  Black anodized.
  105.         16.    Finish:  Kynar 500(tm) coating; color:  ______.
  106.         17.    Finish:  Clad, _______.
  107.         18.    No exposed fasteners.
  108.  
  109.     B.    Header:  Completely enclosing track, operator, and belt drive, with anti-riser stops.
  110.         1.    Track:  1/2 inch (13 mm) wide stainless steel-capped roller track.
  111. NOTE ** Delete one of the following two paragraphs.  The first is for standard and all-glass ("Astro-Slide" and "Astro-Glass").  The second is for telescoping doors ("Astro-Scopic").
  112.         2.    Header Dimensions:  6-3/4 inches (171 mm) high by 4 inches (102 mm) wide; full width of rough opening.
  113.         3.    Header Dimensions:  9 inches (229 mm) high by 6 inches (152 mm) wide; full width of rough opening.
  114.         4.    Provide access door on bottom of enclosure for access to controls and removable components without removal of door or operator.
  115.  
  116.     C.    Doors:  Sliding panels with emergency swing out operation (breakaway) to 90 degrees at any position in opening cycle.
  117. NOTE ** Delete one of the following two types of doors:  extruded aluminum, glazed, or all-glass ("Astro-Glass").
  118.         1.    Door Panels:  Glazed extruded anodized aluminum, with thru-bolted connections, matching header and jambs.
  119. NOTE ** Delete one of the following two paragraphs.  Glazing in doors can be any thickness from 3/16 inch to 1 inch.
  120.             a.    Glass:  1/4 inch (6 mm) clear tempered glass.
  121.             b.    Glass:  1 inch (25 mm) thick sealed insulating units, clear, tempered.
  122.             c.    Rail Height:  5 inches (127 mm); top rails 3-1/2 inches (89 mm).
  123.             d.    Meeting stile weatherstripping:  Dual nylon pile.
  124.             e.    Overlapping stiles of doors and sidelights:  Single nylon pile weatherstripping.
  125.         2.    Door Panels:  1/2 inch (13 mm) thick fully tempered glass.
  126. NOTE ** Delete all but one of the following three paragraphs.
  127.             a.    Clear glass.
  128.             b.    Gray tinted glass.
  129.             c.    Bronze tinted glass.
  130.             d.    Top and bottom rail:  Extruded aluminum, matching header.
  131.             e.    Meeting stile weatherstripping:  None.
  132.             f.    Overlapping stiles of doors and sidelights:  Clear Lexan seals.
  133.         3.    Door Suspension:  1-3/4 inch (44 mm) diameter nylon rollers, mounted over centerline of door, with steel corner support at hinge stile pivot to prevent sag.
  134.         4.    Locking:  Manual lock with interior thumbturn release.
  135. NOTE ** Delete one of the following two paragraphs.  Magnetic latches are standard; ball detent catches are sometimes used instead in high wind areas.
  136.         5.    Latching of Breakaway Panels:  Magnetic latches.
  137.         6.    Latching of Breakaway Panels:  Ball detent catches.
  138. NOTE ** Delete one of the following two paragraphs.  Mechanical spring closer is standard; hydraulic closers should be used with special security locking systems that use breakaway for after-hours egress.
  139.         7.    Breakaway Closer:  Provide mechanical spring closer to return swing out panel to normal sliding position.
  140.         8.    Breakaway Closer:  Provide hydraulic closer to return swing out panel to normal sliding position.
  141.         9.    Limit Arm:  Provide limit arm to prevent swinging to more than 90 degrees.
  142.         10.    Weatherstripping:
  143.             a.    Bottom:  Adjustable nylon sweeps.
  144.             11.    Carrier and header contact surfaces:  Single weatherstripping.
  145. NOTE ** Delete the following paragraph if not required -- it is used to secure the sliding doors from forcible entry while still allowing after-hours egress or entrance.
  146.  
  147.     D.    Security Limited Access Hardware:  Exit device mounted on breakaway panel, electric locking system, and controls.
  148.         1.    Exit Device:  Concealed vertical rod type, mid-panel with muntin in door, or push pad; requiring not more than 8 pounds (35 N) pressure to open; 3/8 inch (9.5 mm) bar travel.
  149.         2.    Electric Lock:  5/8 inch (16 mm) steel bolt in header engaging sliding panel carrier; solenoid operated.
  150.         3.    Two Position Switch:  Switch between day and night control options.
  151.         4.    Day Operation:  Normal operation using actuators.
  152.         5.    Night Operation:
  153.             a.    Outside:  Actuators deactivated; electric lock prevents forcible entry by positively locking sliding panels.
  154. NOTE ** Delete the following paragraph if not required.  Specify what type of actuator is used for night operation -- e.g. card key, key switch, proximity card, etc.
  155.             b.    Outside:  In addition to the above, secure actuator _______ operates doors as in day operation; doors reclose and relock.
  156.             c.    Inside - at door:  Normal actuators deactivated; exit device operates breakaway, complying with NFPA 101 and local codes; swinging panels close and relock after exit.
  157. NOTE ** Delete the following paragraph if not required.  Remote station location should be specified.
  158.             d.    Inside - remote operation:  In addition to above, remote station open/close switch operates electric lock and door; doors reclose and relock.
  159. NOTE ** Delete one of the following two paragraphs.  The first, "fail-secure," is the most common, but the second, "fail-safe," may be required in some circumstances.
  160.         6.    In case of power failure, doors remain locked.
  161.         7.    In case of power failure, doors are unlocked.
  162.  
  163.     E.    Sidelights:  Same construction as doors.
  164. NOTE ** Delete any of the following three paragraphs that are not applicable.  All-glass doors must slide on outside of sidelights.  Sliding doors not requiring breakaway are extremely unusual -- the doors would not qualify as an emergency exit.
  165.         1.    Doors Sliding on Outside of Sidelight:  Provide fixed sidelights; provide doors with side guides using roller bearing pivot assemblies, within sidelight area only.
  166.         2.    Doors Sliding on Inside of Sidelight:  Make sidelights swing out to allow breakaway, with limit arm same as for door; provide floor guides for doors within sidelight area only; provide security latches to positively latch sliding door to sidelite when door is in closed position.
  167.         3.    Doors Not Requiring Breakaway:  Provide doors with side guides using roller bearing pivot assemblies, within sidelight area only.
  168.         4.    Locking function:  When doors are closed and locked, sidelights will not swing out.
  169. NOTE ** Delete all but one of the following four paragraphs.  Normally, the sidelight glazing matches the door glazing.  5/8 inch is the thickest glass that can be used when exit devices are installed on the breakaway panels (see "Security Limited Access Hardware" above).
  170.         5.    Glass:  Same as for doors.
  171.         6.    Glass:  1/4 inch (6 mm) clear tempered glass.
  172.         7.    Glass:  5/8 inch (16 mm) thick sealed insulating units, clear, tempered.
  173.         8.    Glass:  1 inch (25 mm) thick sealed insulating units, clear, tempered.
  174.  
  175.     F.    Door Operators:  Completely electro-mechanical, DC motor powered, with positive pulley and cog belt drive in both opening and closing cycles; comply with ANSI A156.10.
  176.         1.    Provide microprocessor control; do not use rotary cam mechanisms or door position switches in header.
  177.             a.    Adjustable opening and closing speed.
  178.             b.    Hold-open time adjustable from 1 to 30 seconds.
  179.             c.    Adjustable safety reverse:  If object is encountered during closing cycle, re-open door; if object is encountered during opening cycle (in sidelight area), stop door and slowly reclose.
  180.         2.    Provide positive backcheck and latching by pre-set forces that drive the door fully open and closed.
  181.         3.    "On-Off-Hold Open" switch:  Three-position toggle or rocker type.
  182.         4.    Energy Conservation Switch:  Manual switch that reduces door opening width.
  183.         5.    Service conditions:  Satisfactory operation between minus 30 degrees F (minus 34 degrees C) and 160 degrees F (71 degrees C).
  184.         6.    Power supply required:  115 VAC.
  185.  
  186. 2.3    ACTUATORS
  187.  
  188.     A.    Motion Detectors:  Dor-O-Matic "Astro-Scan".
  189. NOTE ** Delete the following if not required - "Astro-Scan One-Way."
  190.         1.    Provide directional movement detection; allow door to close sooner when motion is away from door.
  191. NOTE ** Delete one of the following two paragraphs.  The first is the standard motion detector.  The second is a one-way detector that can distinguish between approaching and departing traffic - this is mostly used for two-way traffic through the same door (a motion detector on each side).
  192.         2.    Operation:  Detect movement within adjustable zone near door and activate operator; deactivate operator upon no movement.
  193.         3.    Operation:  Detect approaching movement within adjustable zone near door and activate operator; deactivate operator upon no movement or departing movement.
  194.         4.    Adjustable sensitivity and time delay.
  195.         5.    Housing:  Black Lexan.
  196.         6.    Lens:  Red Lexan, sealed to provide weather- and dust-proofing.
  197.         7.    Mounting:  Flush against header/wall.
  198.         8.    Operating unit:  Gimbal-mounted oscillator allowing pattern adjustment.
  199.         9.    Electronics:  Removable printed circuit board with gold-plated contacts; unaffected by radio frequency interference, normal police, fire, and ambulance frequencies, and other two-way radio frequencies; designed to eliminate line noise and surge current.
  200.         10.    Service conditions:  Satisfactory operation between minus 30 degrees F (minus 34 degrees C) and 160 degrees F (71 degrees C); unaffected by humidity or moisture.
  201.  
  202.     B.    Push Plate Actuator:  Formed metal plate with rounded corners, satin finish; approximately 5 inches (127 mm) square; with depressed marking.
  203. NOTE ** Delete all but one of the following three paragraphs.  Many other material options are available.
  204.         1.    Material:  Stainless steel.
  205.         2.    Material:  Brass.
  206.         3.    Material:  _________.
  207. NOTE ** Delete one of the following two paragraphs.
  208.         4.    Marking:  "Push to operate door", filled red.
  209.         5.    Marking:  Handicapped symbol, filled blue.
  210.  
  211.     C.    Mat-Type Actuator/Safety:  Manufacturer's standard rubber mat type.
  212.         1.    Frame for recessed mounting in floor slab.
  213.         2.    Frame for surface mounting, with transition strips.
  214.         3.    Color:  As selected from manufacturer's standard selection.
  215.         4.    Color:  _________.
  216.  
  217.     D.    Overhead-Mounted Infrared Presence Detector and Safety Beams:  Dor-O-Matic "Look-See" system with 2 safety beams, interconnected with actuators.
  218.         1.    Housing:  Mounted in door frame (header).
  219.         2.    Detection (safety) zone:  Elliptical shaped, full width of door opening by 30 inches (760 mm) deep, centered on door opening.
  220.         3.    Controls:  Microprocessor.
  221.             a.    Detector or Safety Beam Inoperative:  Prevent open door from closing.
  222.             b.    Object detected in safety zone during door closing:  Re-open door.
  223.             c.    Object detected in safety zone, door open:  Continue to hold door open.
  224.  
  225.     E.    Signs:  Provide signs complying with ANSI A156.10 and applicable codes; white letters on red background.
  226.         1.    Outside:  "AUTOMATIC SLIDING DOOR."
  227.         2.    Inside (push side for breakaway):  "IN EMERGENCY PUSH TO OPEN."
  228.  
  229. PART 3    EXECUTION
  230.  
  231. 3.1    EXAMINATION
  232.  
  233.     A.    Verify that door openings and doors are properly installed and ready for installation of automatic door equipment.
  234.  
  235.     B.    Verify that electrical service is available, properly located, and of proper type.
  236.  
  237. 3.2    INSTALLATION
  238.  
  239.     A.    Install in accordance with manufacturer's instructions; comply with ANSI A156.10.
  240.  
  241.     B.    Grout recess around track.
  242.  
  243.     C.    Install mat-type actuators in recesses in floor, level, and grout securely.
  244.  
  245.     D.    Verify that electrical connections are made correctly.
  246.  
  247. 3.3    ADJUST AND CLEAN
  248.  
  249.     A.    Adjust doors and operators for proper operation, without binding or scraping and without excessive noise.
  250.  
  251.     END OF SECTION
  252. ??
  253.  
  254.  
  255.  
  256.  
  257.  
  258.  
  259.  
  260.  
  261.  
  262.     08462-1